Wood gasifying central heating boiler HOLZ MASTER

HolzMaster is a wood gasifying central heating boiler that offers effectiveness three times higher than when combusting wood in a traditional way.

Efficiency:

90,6%

Output:

20 kW

A+ 5 Class EcoDesign
HOLZ MASTER

Features

HOLZ MASTER

5 Class

5 Class

All boilers have been tested by an independent institute with EU notification to ensure reliable results that are recognized all over the world.

EcoDesign

EcoDesign

EcoDesign 2020 Directive laid down restrictive requirements regarding emission and efficiency what is reflected in boiler actual use during the heating season.

Hydraulics kit

Hydraulics kit

The boiler is fitted with hydraulics kit to ensure quick installation, also where spaces are limited in the boiler room.

Energy savings

Energy savings

Energy-efficient components that reduce energy consumption and save your money.

A+

A+


Description

HOLZ MASTER

Holz Master boiler features with steel heat Exchange that ensures easy operation, high efficiency and long service life. Advantages offered by steel heat exchanger have been combined with modern ceramic furnace. This solution provided the construction of boiler purposed for combustion of solid fuel that offers advantages of both manual loading and biomass fired eco-friendly boilers.

The top chamber provides for combustion chamber where wood is loaded purposed for combustion and gasifying. The door installed at the top allows for wood loading, cleaning and maintenance of top chamber. The chamber is provided in the lower part additionally with the washout hole locked with two wing brackets. The washout hole allows removal of the ash accumulated on the bottom inside the combustion chamber.

The top and lower chamber is separated with ceramic furnace that provides combustion of gases generated as a result of pyrolysis during combustion of wood inside the top chamber. Gases flowing through the furnace are combusted inside the lower chamber. The access door of the lower chamber allows operations, maintenance and cleaning of the chamber and ceramic furnace surfaces.

The pipe heat exchanger installed in the rear consists of vertical flue tubes and it combines the lower chamber with exhaust manifold. The exchanger is fitted with manual cleaning system that facilitates keeping it in clean condition. Exhaust flow from the heat exchanger to exhaust manifold, and then are discharged with exhaust fan to the breeching on the top of boiler.

The exhaust fan supplies the air to the ceramic furnace and combustion chamber. Volume of the air supplied to the furnace and top chamber may be individually controlled with dampers installed on both sides of the boiler. Heating water inlet and outlet purposed for boiler connection to the central heating system is located on boiler rear wall and in top part of boiler, provided with internal threaded G1L” stub pipe. The rear wall of boiler is provided also with exhaust breeching that discharges exhaust gases to the chimney.

The heat exchanger is insulated with mineral wool that protects against heat loss during boiler operation. Boiler casing is provided with high quality powder-coated steel slabs.

Sectional drawing


Characteristics

HOLZ MASTER

Output: 20 kW


Material:

Steel

Feeder:

Firebrick

Burner:

Along with PID algorithm and flue sensor, possible remote control installation

Controller:

Output control, temperature thermostat, 2 heating circuits (+2 circuits optionally), 1 hot water circuit, Internet Wi-Fi (optionally), remote control (optionally)

Fuel:

Efficiency:

Sprawność:

90,6%,

Loading chamber volume:

120 l


Technical Specification

HOLZ MASTER

Dimensions

Model   HM 20
Height: mm 1560
Width: mm 660
Depth: mm 1100

Detailed dimensions

Model   HM 20
Height: mm 1560
Width: mm 660
Depth: mm 1100
A mm 1410
B mm 130
C mm 840



Photos

HOLZ MASTER

Modern heating devices HKS Lazar

Modern heating devices

Articles

Automatic pellet fired stove

Comfort thanks to automatic pellet fired boiler.

Read
Rules for placing heat pumps with R290 propane as a refrigerant on the market

How is the R290 propane heat pump marketed as the refrigerant? What requirements must the device meet in order to be approved for use in our country?

Read

FAQ

How to check anti-freeze fluid level in Smart Fire 11 boiler with central heating function only (without hot domestic water supply). The boiler was not used this winter?

Any fluid loss will be demonstrated with pressure loss indicated by manometer. In case of open circuit, you can also check the level of compression vessel.

Read
Is room temperature sensor included in Eco max 800 t controller set?

Room temperature sensor is available upon separate order.

Read

Find:

Type in a word:

Choose your language:

Choose your language:

Polski Angielski Niemiecki Francuski Czeski

Contact us

Go to contact