MENU

Wood boiler with a large door and spacious loading chamber. HOLZ MASTER S20

HolzMaster S20 is a wood gasification boiler with a large loading chamber, lambda sensor and an efficiency of 93.54%.

Efficiency:

93,54 %

Output:

20 kW

With a ceramic wood gasification burner and a spacious loading chamber


Features

HOLZ MASTER S20

5-year guarantee

5-year guarantee

High-quality materials and modern technologies used in production allow us to extend the warranty on the tightness of the boiler up to 5 years.

Show more Show less
EU Product

EU Product

Show more Show less
EcoDesign

EcoDesign

EcoDesign 2020 Directive laid down restrictive requirements regarding emission and efficiency what is reflected in boiler actual use during the heating season.

Show more Show less
5 Class

5 Class

All boilers have been tested by an independent institute with EU notification to ensure reliable results that are recognized all over the world.

Show more Show less
A+

A+

Show more Show less
Colour touchscreen weather-compensated controller

Colour touchscreen weather-compensated controller

– energy savings and comfortable control.

Show more Show less
Heat exchanger cleaning system

Heat exchanger cleaning system

- easy operation, consistently high efficiency.

Show more Show less
Automatic heat exchanger cleaning

Automatic heat exchanger cleaning

– consistently the highest possible efficiency.

Show more Show less
Induced draft fan

Induced draft fan

– reliable flue gas extraction and safe operation.

Show more Show less
Lambda sensor

Lambda sensor

– maximum combustion efficiency.

Show more Show less
Cooling coil

Cooling coil

– safety and easier installation.

Show more Show less
Ceramic nozzle

Ceramic nozzle

- stable wood combustion with lower emissions.

Show more Show less
Large loading door

Large loading door

– easy loading even of larger logs.

Show more Show less
Internet module

Internet module

(Optionally)
See the relevant data table

– Remote Control and Service Access.

Show more Show less
Integrated hydraulic kit

Integrated hydraulic kit

(Optionally)
See the relevant data table

- thermostatic valve and energy-efficient pump.

Show more Show less

Description

HOLZ MASTER S20

HolzMaster S20 is a high-capacity, highly efficient wood gasification boiler designed with ecology, safety and maximum user comfort in mind. Its spacious loading chamber with a large door allows convenient loading even of thick logs, significantly extending operating time on a single fuel load and reducing the frequency of servicing. The ceramic burner makes optimum use of the energy contained in the wood gas produced during the gasification process, delivering real savings and clean heating.

Boiler operation is managed by an advanced controller which, together with a lambda probe and flue gas temperature sensor, precisely regulates the air supply to ensure high efficiency, safety and stable combustion. Standard equipment includes a cooling coil that protects the system, simplifies installation and reduces installation costs. The boiler is also equipped with an exhaust fan that effectively minimises the risk of flue gas backflow when the door is opened, helping to keep the boiler room clean.

Show more Show less

Characteristics

HOLZ MASTER S20

Model identifier HM S 20
Energy efficiency class A+
Rated thermal output 20 kW
Energy efficiency coefficient 119,08
Seasonal space heating energy efficiency 81,02%

Technical Specification

HOLZ MASTER S20

Parameters Unit HM S 20
Boiler class - 5
Thermal efficiency % 93,54
Nominal output kW 20
Fuel consumption at nominal output kg/h 5,45
Width mm 605
Height mm 1185
Depth mm 1290
Weight kg 500
Loading chamber dimensions:
width | height | depth
mm 415 | 500 | 545
Loading chamber capacity dm³ 113
Flue outlet diameter external/internal mm 120/110
Required chimney draft Pa/mbar 15/0,15
Supply and return inch 1
Maximum operating pressure bar 3
Average flue gas temperature at nominal output °C 92,50
Maximum boiler temperature °C 85
Recommended boiler temperature °C 70÷80
Water capacity dm³ 80
Minimum return water temperature °C 65
Show more Show less

Modern heating devices HKS Lazar

Modern heating devices

Articles
Class 5 and EkoDesign provides a new benchmark for central heating boilers

Unfortunately Poland has some of the worst air quality in Europe. The extent of the problem has been confirmed by World Health Organization Report based on data regarding the beginning of 2016. An astonishing 33 of Europe’s 50 most-polluted towns are in Poland and Polish town was ranked as the most polluted, what confirms how serious and huge is the problem.

Read
You can reduce smog also – by using pellet fired boiler

Coal heating in houses is largely to blame for smog in Poland, that is mainly dark fumes rising from chimneys. It is so-called “low” emission from uneconomical household furnaces, stoves and boilers. According to statistics it is the households that generate more than 50% of emissions of particulate matter and almost 90% of carcinogenic benzo(a)pyrene.

Read
FAQ
How to check anti-freeze fluid level in Smart Fire 11 boiler with central heating function only (without hot domestic water supply). The boiler was not used this winter?

Any fluid loss will be demonstrated with pressure loss indicated by manometer. In case of open circuit, you can also check the level of compression vessel.

Read
Is 190oC temperature of flue gas in Lazar branded pellet fired boiler allowed?

This temperature is possible, if the heat exchanger gets dirty and boiler has been in operation for few hours at total output (at low outdoor temperature). In this case clean the boiler and check...

Read

Find:

Choose your language:

Choose your language:

Polski Angielski Niemiecki Francuski Czeski

Contact us

Go to contact