Equipment HYGIENIC DHW TANKS TH02 i HH02

They are used to store energy and produce DHW water using a corrugated stainless steel coil. Polyurethane foam insulation, leatherette housing.
HYGIENIC DHW TANKS TH02 i HH02

Characteristics

HYGIENIC DHW TANKS TH02 i HH02

Tank: TH02 / 300 / 4
TH02 / 500 / 5
TH02 / 800 / 5
Nominal capacity (L): 300 500 800
Spiro coil - surface (m2): 4,0 5,0 5,0
Spiro coil - capacity (L): 18 23 23
Max. temp. and working pressure of the spiro coil: 95ºC / 6 Bar 95ºC / 6 Bar 95ºC / 6 Bar
Max. tank temperature and working pressure: 95ºC / 3 Bar 95ºC / 3 Bar 95ºC / 3 Bar
Isolation: PUR Removable Removable
Weight (kg): 116 126 180
Optional electric heater. G.K.2,0(6/4) / G.K.4,5(6/4) / G.K.6,0(6/4) / G.K.9,0(6/4) G.K.2,0(6/4) / G.K.4,5(6/4) / G.K.6,0(6/4) / G.K.9,0(6/4) G.K.2,0(6/4) / G.K.4,5(6/4) / G.K.6,0(6/4) / G.K.9,0(6/4) / G.K.12(6/4)
Energy class: C C C
Particular precautions when assembling, installing or maintaining the buffer tank: Observe all assembly, installation and maintenance requirements in the equipment manual.
Tank: HH02 / 800 / 5 / 2,8
Nominal capacity (L): 800
Spiro coil - surface (m2): 5,0
Spiro coil - capacity (L): 23
Max. temp. and working pressure of the spiro coil: 2,8
Max. tank temperature and working pressure: 14,3
Isolation: 95ºC / 6 Bar
Weight (kg): 95ºC / 3 Bar
Optional electric heater. Removable
Energy class: 237
Opcjonalna grzałka elekt. G.K.2,0(6/4) / G.K.4,5(6/4) / G.K.6,0(6/4) / G.K.9,0(6/4) / G.K.12 (6/4)
Klasa energetyczna: C
Particular precautions when assembling, installing or maintaining the buffer tank: Observe all assembly, installation and maintenance requirements in the equipment manual.

Technical Specification

HYGIENIC DHW TANKS TH02 i HH02

wymiary_zb_higieniczny.png

A B C D E F G H I J K N
TH02/300/4 1610 1375 750 550 1000 625 250 250 625 1000 1375 250
TH02/500/5 1770 1495 810 650 1075 655 240 240 625 1075 1495 250
TH02/800/5 1890 1589 690 800 1156 723 290 290 723 1156 1589 250
HH02/800/5/2,8 1890 1589 690 800 1156 723 290 290 723 1156 1589 250
Modern heating devices HKS Lazar

Modern heating devices

Articles

Class 5 and EkoDesign provides a new benchmark for central heating boilers

Unfortunately Poland has some of the worst air quality in Europe. The extent of the problem has been confirmed by World Health Organization Report based on data regarding the beginning of 2016. An astonishing 33 of Europe’s 50 most-polluted towns are in Poland and Polish town was ranked as the most polluted, what confirms how serious and huge is the problem.

Read
You can reduce smog also – by using pellet fired boiler

Coal heating in houses is largely to blame for smog in Poland, that is mainly dark fumes rising from chimneys. It is so-called “low” emission from uneconomical household furnaces, stoves and boilers. According to statistics it is the households that generate more than 50% of emissions of particulate matter and almost 90% of carcinogenic benzo(a)pyrene.

Read

FAQ

How to check anti-freeze fluid level in Smart Fire 11 boiler with central heating function only (without hot domestic water supply). The boiler was not used this winter?

Any fluid loss will be demonstrated with pressure loss indicated by manometer. In case of open circuit, you can also check the level of compression vessel.

Read
Is 190oC temperature of flue gas in Lazar branded pellet fired boiler allowed?

This temperature is possible, if the heat exchanger gets dirty and boiler has been in operation for few hours at total output (at low outdoor temperature). In this case clean the boiler and check...

Read

Find:

Type in a word:

Choose your language:

Choose your language:

Polski Angielski Niemiecki Francuski Czeski

Contact us

Go to contact